NEMA letter designations following frame number

NEMA 48/56 Hub, Flange, and Close-coupled Pump Shaft Dimensions

NEMA 48K and 56K hub
dimensions sump pump motors NEMA 48M, 48N and 56N
flange mount dimensions

Oil
Burner
Motors

48M

48N, 56N

AJ

6 3/4inches

7 1/4inches

BD

6 1/4max.

7 max.

Ak

5 1/2

6 3/8

CE

7 3/4max.

8 1/4max.

Close-coupled pump shaft
dimensions

Dimensions (inches)

Frame Designations

U

EL

EM

EN

EQ

ET

AH

AJ

AK

BD

BF

143JM/145JM

7/8

1 5/32

1

3/8-16 X 3/4

5/8

2 7/8

4 1/4

5 7/8

4 1/2

6 5/8

3/8-16

143JP/145JP

7/8

1 5/32

1

3/8-16 X 3/4

1 9/16

5 15/16

7 5/16

5 7/8

4 1/2

6 5/8

3/8-16

182JM/184JM

7/8

1 1/4

1

3/8-16 X 3/4

5/8

2 7/8

4 1/4

5 7/8

4 1/2

6 5/8

3/8-16

182JP/184/JP

7/8

1 1/4

1

3/8-16 X 3/4

1 9/16

5 15/16

7 5/16

5 7/8

4 1/2

6 5/8

3/8-16

213JM/215JM

7/8

1 1/4

1

3/8-16 X 3/4

5/8

2 7/8

4 1/4

7 1/4

8 1/2

9

1/2-13

213JP/215JP

1 1/4

1 3/4

1 3/8

1/2-13 X 1

2 3/8

5 7/8

8 1/8

7 1/4

8 1/2

9

1/2-13